Step
Procedure
1.
Check bus termination
2.
If necessary, adjust software compatibility
3.
Set controller address
4.
Set baud rate
5.
Inhibit basic device via
terminal 28 (CINH).
6.
Connect the separate
voltage supply for the
function module
(switch on DeviceNet)
7.
Connect mains voltage and
check status displays
8.
Configure host for
communication with the
function module with the
configuration software.
9.
l
With explicit messages" all parameters can be read or written from the drive and/or
function module.
l
The I/O data can be used to
– read actual values (e.g. status word) or
– write setpoints (e.g. frequency setpoint).
10.
Configure the process data
channel of the basic device
(see "Application range")
for operation with the
function module.
11.
If necessary, assign the process output data of the master/scanners to the input signals of
the basic device under C1511.
12.
If necessary, assign the process input words of the master/scanner to the output signals
of the basic device under C 1510.
EDK82ZAFVC010 DE/EN/FR 2.0
Note
Terminal 28 on LOW potential.
The basic device can be inhibited and enabled via the bus
Directly after the voltage supply for the function module
has been connected two LEDs on the front go on for a short
time in the indicated order:
l
The LED Status of connection with bus" changes its
colour from green to red before it goes off.
l
The LED "Status of the connection to the basic device"
changes its colour from green to red before it goes off.
l
The LED Status of connection with bus" on the front of
the function module is blinking (only 8200 vector).
l
The green LED Status of connection with basic device"
on the front of the function module is on (only 8200
vector).
dc
l
Keypad:
(if attached)
Response
l
The LED Status of connection with bus" on the front of
the function module changes from blinking to on.
Recommendation:
Set code C0005 = 200 after the Lenze setting has been
loaded (C0002).
C0005 = 200 preconfigures the device for the operation with
a function module. Control and status words are already
linked.
Continue with step 14.
l
Commissioning
4
61