Accessories; Error Analysis / Error Display / Service Indicator; Further Possible Errors When Using The Unit; Maintenance / Care / Cleaning - Ardo Carum Mode D'emploi

Masquer les pouces Voir aussi pour Carum:
Table des Matières

Publicité

Les langues disponibles
  • FR

Les langues disponibles

  • FRANÇAIS, page 28
en

6. ACCESSOrIES

Mains cable Euro
Mains cable UK
Mains cable UL
Trolley - optional
Car battery adapter 12VDC - optional
Bottle holder
EasyFreeze holder
Various pumpsets

7. ErrOr AnAlYSIS / ErrOr DISPlAY / SErvICE InDICAtOr

Identifiable errors or service / maintenance schedules are represented on the LCD by a warning triangle.
Switch the unit off, and then on again. If the error message comes up again, return the unit to the
supplier. The unit must be repaired by trained service personnel, or by the manufacturer.
Error: the unit does not work on battery power i.e. the pump does not operate.
Solution: Connect the unit to the mains to recharge the battery. The battery charging time is ca.
4 hrs. Advice: The unit may be used while the battery is being charged, but this will extend the
charging time.

7.1. Further possible errors when using the unit

• Weak or absent vacuum
Disconnect the PumpSet from the unit. Partly close the connector opening with a finger to test the suction.
If suction is de-tectable, then the pump is working. Test the PumpSet in accordance with the separate
instructions, (only use the original ARDO PumpSet)
• The pump is not working / no data on the LCD display
Check the mains supply; if the unit still does not work, it is defective
Should any of these errors occur, and be confirmed, return the unit to the supplier immediately. The unit must be
repaired by trained service personnel or by the manufacturer.

8. MAIntEnAnCE / CArE / ClEAnIng

The silicone pot integrated into the PumpSet constitutes a total barrier, and ensures that neither breast milk nor
pathogenic agents can get into the pump unit. The unit is maintenance-free; care of the unit, and its accessories,
is limited to inspection and cleaning.
The Carum breast pump can be repaired, but only by trained service personnel or by the manufacturer. For
this reason, only the bottle holder, the EasyFreeze holder, the connector cable, and the car charging cable, are
available for order as spare parts. See Section: Accessories / Spare Parts.
Art. No. 63.00.130
Art. No. 63.00.131
Art. No. 63.00.132
Art. No. 63.00.129
Art. No. 63.00.133
Art. No. 63.00.127
Art. No. 63.00.128
www.ardomedical.com
25
en
Ardo medical AG

Publicité

Table des Matières
loading

Table des Matières