Declaration of compliance
The manufacturer declares that the appliances of their production are compliant with the above
mentioned EEC directives and requires that installation be done observing the norms in force,
particularly regarding the system for letting out fumes and air exchange.
DESCRIPTION OF APPLIANCES
Gas Bain marie
A sturdy structure in steel placed on four feet which make it possible to regulate the height in the
version with cabinet. The external coating is in Chrome-Nickel 18-10 stainless steel.
The burner is provided with a thermostatic safety gas tap which enables the regulation of the
temperature in a range from 45° C inclusive to 90° inclusive; safety is ensured by means of a
thermocouple which is kept active by the flame of the pilot burner.
The vat is made entirely of stainless steel.. The chamber is heated by means of a stainless steel
tubular burner, suitable for proper functioning at the high temperatures to which it is exposed.
Electric Bain marie
A sturdy structure in steel placed on four feet which make it possible to regulate the height in the
version with cabinet. The external coating is in Chrome-Nickel 18-10 stainless steel.
The vat is made entirely of stainless steel. It is heated by an electric immersion heater activated by a
thermostat. This thermostat makes it possible to regulate the temperature in a range from 30°C to
90°C.
Neutral cabinet
In the standing versions, doors are available for closing the compartment to create a neutral cabinet.
There are also racks available for inserting GASTRONORM wash bowls.
PROVISIONS FOR INSTALLATION
Place (fig. 5, pag. 3)
It is advisable to install the appliance in a well- ventilated room or under an extractor hood. The
appliance may be installed as a single unit or together with others. In both cases, if it is installed
near a wall of inflammable material, a minimum distance of 150 mm from the side and back walls
must be observed. In the event that it is not possible to observe this distance, protective measures
must be taken (e.g. use of sheets of refractory material) which ensure that the temperature of the
walls is within the established safety limits.