Warm Tech PAP24000 Mode D'emploi page 86

Table des Matières

Publicité

Les langues disponibles

Les langues disponibles

All the stoves' air input pipe diameter is 50 mm, venting pipe diameter is ¢80 mm. The total length of
pipes is no longer than 3m and elbows are not available. Indoor venting pipe joint should be sealed by
silicone sealant to prevent exhaust leaking into the room. Venting pipe and termination should be
waterproof and avoid being blocked. Or, the stove can not work properly. When the installation is
limited by space or the owner's special requirements and the pipes' length should be longer than 3m
and need elbows, the diameters of the air input pipe and venting pipe must be increased properly for
smooth convection. If not, it will influence the burning and the stove can not work properly. The owner
should connect with the local seller for the right installation. When pellet stove is normal working, the
temperature on venting pipe surface can reach 200˚C, so the combustible things, clothes and furniture
should be away from the venting pipe. To prevent scald, don't touch the heating surface!
Vent Termination Requirements
(1)Do not terminate the vent in any enclosed or semi enclosed areas such as a carport, garage, attic,
crawlspace, narrow walkway, closely fenced area, under a sundeck or porch, or any location that can
build up a concentration of fumes such as stairwells, covered breezeway,etc.
(2)Vent surfaces can become hot enough to cause burns if touched. Noncombustible shielding or
guards may be required.

Publicité

Chapitres

Table des Matières
loading

Ce manuel est également adapté pour:

Pap30000Pap24001

Table des Matières