8 The blower still works
after the stove is cool and
fuel feed stops.
9 no enough heat wind
10. Showing "Pressure
Erro" on the display
ELECTRICAL GENERATOR OPERATION
Your stove can be powered with a gas driven electrical generator.
However, the generator's electrical regulator may not be compatible with the stove's
electronics. The higher the quality of the generator, the greater the chance that it is compatible
with the stove.
The low temperature
switch (30˚C) is broken.
Unqualified fuel
Blower speed is too high.
Heat exchange tubes are
dirty.
Vent pipe is blocked
The door is opening
The are some leakages
Change this switch.
Use the standard specially pellet.
Use higher power
Clean the heat exchange tubes.
Shut down the stove, check the
venting pipe
Close the door and unplugged then
restart
Check it and repair it.
Adjust the combustion fan's speed
up to offer more pressure in the
stove