Proper Use; Technical Data; Before Starting The Equipment - EINHELL TE-AC 36/6/8 Li OF Set Instructions D'origine

Masquer les pouces Voir aussi pour TE-AC 36/6/8 Li OF Set:
Table des Matières

Publicité

Les langues disponibles
  • FR

Les langues disponibles

  • FRANÇAIS, page 25
Original operating instructions
Safety information

3. Proper use

The cordless compressor is designed to generate
compressed air for compressed air driven tools.
The equipment is to be used only for its prescri-
bed purpose. Any other use is deemed to be a
case of misuse. The user / operator and not the
manufacturer will be liable for any damage or inju-
ries of any kind caused as a result of this.
Please note that our equipment has not been de-
signed for use in commercial, trade or industrial
applications. Our warranty will be voided if the
machine is used in commercial, trade or industrial
businesses or for equivalent purposes.

4. Technical data

Mains voltage ......................................... 36 V DC
Compressor speed min
Operating pressure bar: ............................ max. 8
Pressure vessel capacity (in liters): .................. 6
Theoretical suction rate l/min.: ..................... 130
Output (compressed air) at 7 bar: .... 38 liters/min
Output (compressed air) at 4 bar: .... 55 liters/min
Sound power level L
WA
Uncertainty K
....................................... 2.23 dB
WA
Sound pressure level L
Uncertainty K
........................................ 2.23 dB
pA
Protection type: ........................................... IPX0
Weight of the unit in kg: ....................approx. 10.5
Danger!
Noise
The noise emission values were measured in ac-
cordance with EN ISO 3744.

5. Before starting the equipment

Before you connect the equipment to the power
supply make sure that the data on the rating plate
are identical to those of the rechargeable battery.
Check the equipment for damage which may
have occurred in transit. Report any damage
Anl_TE_AC_36_6_8_Li_OF_SPK13.indb 17
Anl_TE_AC_36_6_8_Li_OF_SPK13.indb 17
: ........................... 3200
-1
in dB: .......................... 94
in dB: ...................... 73
pA
- 17 -
GB
immediately to the transport company which
was used to deliver the compressor.
Install the compressor in the vicinity of the
point of consumption.
Avoid long air lines.
Make sure that the intake air is dry and dust-
free.
Do not install the compressor in a damp or
wet room.
The compressor may only be used in suitable
rooms (with good ventilation and an ambient
temperature from +5 °C to 40 °C). There must
be no dust, acids, vapors, explosive gases or
inflammable gases in the room.
The compressor is designed to be used in dry
rooms. It is prohibited to use the compressor
in areas where work is conducted with spray-
ed water.
Operate the equipment only on a firm, level
surface.
Use flexible hoses in order to prevent trans-
mitting unacceptable loads to the pipeline
system at the connection between the com-
pressor system and the pipeline system.
It is essential to use separators, traps and
drains which process the liquids produced by
the compressor before the compressor sys-
tem is put into operation.
Supply hoses at pressures above 7 bar
should be equipped with a safety cable (e.g.
a wire rope).
5.1 Charging the battery (Fig. 3)
1. Take the battery pack out of the equipment.
Do this by pressing the side pushlock buttons.
2. Check that your mains voltage is the same as
that marked on the rating plate of the battery
charger. Insert the power plug of the charger
(d) into the socket outlet. The green LED will
then begin to fl ash.
3. Slot the battery pack (12) onto the battery
charger (d).
4. In the section entitled „Charger indicator" you
will fi nd a table with an explanation of the LED
indicator on the charger.
The battery pack can become a little warm during
the charging. This is normal.
If the battery pack fails to charge, check:
whether there is voltage at the socket outlet
whether there is good contact at the charging
contacts
19.04.2022 08:43:54
19.04.2022 08:43:54

Publicité

Table des Matières
loading

Ce manuel est également adapté pour:

40.204.50

Table des Matières