The alarm will reset upon the closure of the door and is registered in memory (HACCP
icon turned on fixed).
Press the up and down buttons simultaneously for more than 3 seconds
and then up or down to access the list of Alr registered alarms, including
those of blackouts identified by the initials dA.
Note: Alr is present on the SMART menus only when the HACCP icon is
permanently lit on the display (flashing in the event of an alarm in
progress, following another event that has already occurred)
Press the enter key to display the maximum compartment temperature
reached during door opening.
Note: since up to 10 events can be stored in memory, additional events can overwrite
older events.
The HACCP led can be reset to normal (off) only after all the new alarms that have
occurred have been displayed.
It is possible to exit the alarm display by repeatedly pressing the ON/stand-by key twice.
HIGH CONDENSATION TEMPERATURE ALARM
If the condensation temperature is too high, due to dirty condenser, the label [HtC] and the
room temperature alternate on the display.
The buzzer sounds.
The buzzer can be turned off by pressing the key
The visual warning signal stays on until the condensation tempertaure returns to normal
range.
CONDENSER DIRTY ALARM
If the condensation temperature is too high because the condenser is very dirty, the label
[dCA] alternating with the cell temperature will be shown on the display. A buzzer is also
activated.
The buzzer can be turned off by pressing the key
The visual warning signal stays on until the condensation tempertaure returns to normal
range.
In parallel, the operating set point of the device changes automatically to safeguard plant
conditions.
The new setting remains until the condensation temperature returns within the normal
range.
HIGH PRESSURE ALARM
If a refrigeration system pressure is detected that is higher than the limit values, due to an
extremely dirty condenser or a damaged condenser fan, the label [HP] alternating with the
cell temperature will be shown on the display. A buzzer is also activated.
.
.
25