The visual alarm signal stays on until the temperature returns within the normal range.
HIGH AND LOW TEMPERATURE ALARMS MEMORIZED
A steady lit HACCP icon indicates that a high temperature [AH] or low
HACCP
temperature alarm [AL] has occurred.
Press the up and down buttons simultaneously for more than 3 seconds
and then Up or Down to access the list of Alr registered alarms,
including high and low temperature alarms.
Note: Alr is present on the SMART menus only when the HACCP icon is
permanently lit on the display (flashing in the event of an alarm in
progress, following another event that has already occurred).
Press the enter key to view the first recorded alarm event.
Note: an alphanumeric string in which the first 2 characters identify the
type of alarm and the last character defines the time position assigned
to the event in the alarm list through a number from 0 to 9.
The lowest digit (0) refers to the most recent alarm.
High and low alarms are identified by the letters AH and AL.
Scroll down the list of events with the up button and take into
consideration those starting with AH or AL
In correspondence with each of them, press the enter key to
dynamically display the information relating to the recorded critical
temperature, the date/time of alarm recording and, subsequently, the
duration of the event, expressed in hours and minutes. At the end of
data scrolling, the alarm event examined is shown again on the display..
Note: if the rtc module is not present on-board (Hr0 = 0, real time clock
absent), the information relative to the date/time will be missing.
Press the up button to scroll through the other alarm events.
Press the enter key in correspondence with another AH or AL alarm
event to display the information.
Note: since up to 10 events can be stored in memory, additional events can overwrite
older events.
The HACCP led can be reset to normal (off) only after all the new alarms that have
occurred have been displayed.
It is possible to exit the alarm display by repeatedly pressing the ON/stand-by key twice.
If the high temperature alarm is on, the compressor keeps working; if the low temperature
alarm is on, the compressor stops.
! If the card is set to the stand-by mode, the min. / max. temperature memorized and
any alarms will not be saved.
23