Use the keys
only.
Press the enter key to exit or confirm the selection of the parameter new
value; the setting stops blinking.
On starting the appliance, a "LAMPTEST" phase will start.
A 60-second time window opens. During this time, when you put the
machine in stand-by and then press the up key for 10 seconds, the label
[rLd] appears on the display.
Press the enter key for two seconds: the reset map loads and the
buzzer makes 3 consecutive beeps. At this point, the [rLd] label
disappears and the machine regularly returns to stand-by.
UNIT WITH BROKEN SENSOR PROBES DURING CONSERVATION
Room probe error
If the room probe is broken or the relevant connection interrupted, the display shows the
label [E0].
The compressor keeps operating in storing according to the values given to parameters
C5 and C6.
The evaporator fan continues to run in parallel with the compressor.
Evaporator fan error (only on -22°C / +5°C units)
If the room probe is broken or the relevant connection interrupted, the display shows the
label [E1].
The inner fan operates according to the value given to parameter "F0"
As F0 = 2, depending on parameters C4 and C5 with compressor.
Condenser probe error
If the condenser probe is broken or the relevant connection interrupted, the display shows
the label [E2].
The condenser fan continues to run in parallel with the compressor with delay when the
compressor is switched off if F12>0 and in any case without looking at the temperature on
the condenser.
Note: if more than one probe is broken or interrupted, the relative labels will be shown
sequentially on the display.
to select the new value, applicable to parameters
DEFAULT PARAMETER RECOVERY

ALARMS

21