BLACKOUT ALARM IN PROGRESS
If the temperature is higher than |SetPoint + r0 + A2| when the board is switched on again
after a blackout, a Black Out Alarm is triggered due to power failure after a specific amount
of time A10.
The anomalous event is signalled on the display by alternating the actual cell temperature
with the BLO label.
A buzzer is activated:
> Intermittently for the time set with parameter A5, if parameter u9 = 1
> Always, for the entire duration of the alarm if A5 = 0
Press the Enter key the first time to silence the buzzer.
Press it again to display the maximum recorded compartment
temperature.
Press it again to reset the alarm: the display returns to the actual cell
temperature.
RECORDED BLACKOUT ALARM
The recorded blackout alarm is made evident because the HACCP LED will be steadily lit
on the display.
It is always possible to see the details once the alarm has been reset.
Press the up and down buttons simultaneously for more than 3 seconds
and then Up or Down to access the list of Alr registered alarms,
including those of blackouts identified by the initials bL.
Note: Alr is present on the SMART menus only when the HACCP icon is
permanently lit on the display (flashing in the event of an alarm in
progress, following another event that has already occurred).
Press the Enter key to display the maximum compartment temperature
reached during the blackout.
Note: since up to 10 events can be stored in memory, additional events can overwrite
older events.
The HACCP led can be reset to normal (off) only after all the new alarms that have
occurred have been displayed.
It is possible to exit the alarm display by repeatedly pressing the ON/stand-by key twice.
OPEN DOOR ALARM
In case of open door alarm the display visualises the message [dA] alternating with the
current visualisation whilst the buzzer sounds the event with a beep of five seconds
repeated every 10.