Safety Instructions; Description And Specifications; Engineering Data; Discharge - Xylem GOULDS GT IRRI-GATOR Manuel D'instructions

Table des Matières

Publicité

Les langues disponibles

Les langues disponibles

SAFETY INSTRUCTIONS

TO AVOID SERIOUS OR FATAL PERSONAL INJURY OR
MAJOR PROPERTY DAMAGE, READ AND
FOLLOW ALL SAFETY INSTRUCTIONS IN MANUAL
AND ON PUMP.
This is a SAFETY ALERT SYMBOL. When
you see this symbol on the pump or in the
manual, look for one of the following signal
words and be alert to the potential for
personal injury or property damage.
Warns of hazards that WILL cause serious
DANGER
personal injury, death or major property
damage.
Warns of hazards that CAN cause serious
WARNING
personal injury, death or major property
damage.
Warns of hazards that CAN cause personal
CAUTION
injury or property damage.
NOTICE: Indicates special instructions which are very
important and must be followed.
THIS MANUAL IS INTENDED TO ASSIST IN THE IN-
STALLATION AND OPERATION OF THIS UNIT AND
MUST BE KEPT WITH THE PUMP.
THOROUGHLY REVIEW ALL INSTRUCTIONS AND
WARNINGS PRIOR TO PERFORMING ANY WORK
ON THIS PUMP.
MAINTAIN ALL SAFETY DECALS.
NOTICE: INSPECT UNIT FOR DAMAGE AND REPORT
ALL DAMAGE TO THE CARRIER OR DEALER
IMMEDIATELY. DO NOT USE PUMP IF
DAMAGE IS SUSPECTED.
UNITS NOT DESIGNED FOR USE
WARNING
WITH HAZARDOUS LIQUIDS OR
FLAMMABLE GASES.
Hazardous Fluids
can cause fire,
burns or death.
This product can expose you to
WARNING
chemicals including Lead, which is known to
the State of California to cause cancer and birth defects
or other reproductive harm.
For more information go to: www.P65Warnings.ca.gov.

DESCRIPTION AND SPECIFICATIONS

The Model GT embraces a line of end suction, single
stage, self-priming centrifugal pumps for lawn sprin-
kling, HVAC systems, and general water transfer.
Casing is cast iron construction with tapped openings
provided for vacuum gauge and casing drain.
Impellers are enclosed design, glass filled Noryl TM ,
threaded directly on motor shaft.
Standard motors are NEMA standard, 3500 RPM, open
drip proof enclosure.

ENGINEERING DATA

Model
HP
Ph/Hz
GT07
¾
GT10
1
GT15
1/60
GT20
2
GT30
3
GT073
¾
GT103
1
GT153
3/60
GT203
2
GT303
3
Maximum Liquid Temperature: 160ºF (71ºC)
Maximum Starts per Hour: 20 – evenly distributed
PIPING
Pump MUST be installed horizontally on a solid flat
surface, with discharge on top.
Allow adequate space for servicing and ventilation.
Protect the unit from weather and water damage due
to rain or flooding or freezing temperatures.
Piping should be no smaller than the suction and dis-
charge connections and kept short as possible, avoid-
ing unnecessary fittings to minimize friction losses.
All piping MUST be independently supported and
MUST NOT place any piping loads on the pump.
NOTICE: DO NOT FORCE PIPING INTO PLACE AT
PUMP SUCTION AND DISCHARGE
CONNECTIONS.
All pipe joints MUST be airtight.
The use of Teflon TM tape, or equivalent, is recom-
mended for ALL pipe joints.
SUCTION
Total suction lift, including elevation and pipe friction
loss, should not exceed 25 feet of head.
Install an airtight union in the suction line close to the
pump. See Figure 1.
Installation of a foot valve at liquid source is recom-
mended.
NOTICE: FOR INSTALLATIONS WITH LONG SUC-
TION PIPING, BOTH A FOOT VALVE AND A
CHECK VALVE ARE RECOMMENDED.
To avoid air pockets, no part of the piping should be
above the pump suction connection and piping should
slope upward from liquid source.
For installations with long suction piping, fill the suction
pipe with water before connecting to pump.

DISCHARGE

Install a tee at the discharge connection of the pump.
The top opening of the tee is required for initial prim-
ing. See Figure 1.
Suction
Discharge
Wt. lbs.
48
52
60
65
76
1½" NPT
1½" NPT
49
52
55
69
71
3

Publicité

Table des Matières
loading

Table des Matières