Safety Instructions; Nameplate - Xylem GOULDS e-SV Manuel D'instructions

Table des Matières

Publicité

Les langues disponibles

Les langues disponibles

SAFETY INSTRUCTIONS

TO AVOID SERIOUS OR FATAL PERSONAL
INJURY OR MAJOR PROPERTY DAMAGE, READ
AND FOLLOW ALL SAFETY INSTRUCTIONS IN
MANUAL AND ON PUMP.
THIS MANUAL IS INTENDED TO ASSIST IN THE
INSTALLATION AND OPERATION OF THIS UNIT
AND MUST BE KEPT WITH THE PUMP.
This is a SAFETY ALERT SYMBOL.
When you see this symbol on the pump
or in the manual, look for one of the
following signal words and be alert
to the potential for personal injury or
property damage.
Warns of hazards that WILL cause
DANGER
serious personal injury, death or major
property damage.
Warns of hazards that CAN cause
WARNING
serious personal injury, death or major
property damage.
Warns of hazards that CAN cause per-
CAUTION
sonal injury or property damage.
NOTICE: INDICATES SPECIAL INSTRUCTIONS
WHICH ARE VERY IMPORTANT AND
MUST BE FOLLOWED.
THOROUGHLY REVIEW ALL INSTRUCTIONS
AND WARNINGS PRIOR TO PERFORMING ANY
WORK ON THIS PUMP.
MAINTAIN ALL SAFETY DECALS.
UNIT NOT DESIGNED FOR USE
WARNING
WITH HAZARDOUS LIQUIDS OR
FLAMMABLE GASES. THESE
FLUIDS MAY BE PRESENT IN
CONTAINMENT AREAS.
Hazardous fluids can
cause fire, burns
or death.
The purpose of this manual is to provide the neces-
sary information for proper installation, operation and
maintenance of the e-SV pump. The instructions and
warnings provided below concern the standard version,
as described in the sale documents. Special versions may
be supplied with supplementary instructions leaflets.
Please refer to the sale contract for any modifications or
special version characteristics. Always specify the exact
pump type and identification code when requesting
technical information or spare parts from our Sales and
Service department. For instructions, situations or events
not considered in this manual or in the sale documents,
please contact your distributor.
Read this manual before installing and using
the product. Improper use may cause personal
injury and damage to property and lead to the
forfeiture of the warranty coverage.
The e-SV pump is a vertical multistage, non-self priming
pump which can be coupled to standard electric motors.
For the pump sizes 1SV-22SV , some of the metal parts
that are in contact with the pumped liquid are made of
stainless steel, others are made of cast iron. They are
available in different versions according to the position
of the suction and delivery ports and the shape of the
connection flanges. For the sizes 33SV-125SV , some of
the metal parts in contact with the pumped liquid are
made of stainless steel, others are made of cast iron. A
special version is available, in which all the metal parts
in contact with the pumped liquid are made of stainless
steel. If you purchase a pump without the electric motor,
make sure that the motor you use is suitable for coupling
to the pump. All e-SV pumps are equipped with a special
mechanical seal designed for easy replacement without
having to disassemble the entire pump.
These pumps are suitable for civil and industrial water
distribution systems, pressure booster, irrigation (agri-
culture, sporting facilities), water treatment, boiler feed,
parts washing, cooling - air conditioning - refrigeration
and fire fighting applications. The factory may be able
to configure certain models for pumping liquids having
atypical water and/or wastewater characteristics (e.g.,
acidic, basic, petrochemical or other non-aqueous liquids,
etc.). Any such specialty use requires consultation with
factory and engineering personnel for a detailed applica-
tion-specific evaluation.

1. NAMEPLATE

Do not use this pump/electric pump unit to
handle flammable and/or explosive liquids.
Do not use this pump to handle liquids
WARNING
containing abrasive, solid or fibrous
substances.
1
Goulds Water Technology Catalog Number
2
Capacity Range
3
TDH Range
4
Rated Speed
5
Rated Horsepower
6
Maximum Operating Pressure
7
Maximum Operating Temperature
8
Pump Serial Number
Confirm that the pump is capable of meeting the desired
operating conditions.
1. MINIMUM INLET (SUCTION) PRESSURE
In general, the minimum suction pressure required
is that which provides adequate NPSH
feed the pump. The required NPSHr, expressed in
feet, can be found on the performance curve for the
pump at the specific duty point. It is recommended
necessary to
A
7

Publicité

Chapitres

Table des Matières
loading

Table des Matières