Additional modules
● Storage
● Transport
Vibration resistance
● Harmonic oscillations
(sine wave) according to
IEC 60068-2-6
● Permanent shocks according to
IEC 60068-2-29
Torque for cable gland nut made of Plastic
Housing protection type
For connecting to circuits with the
following peak values
Effective internal capacitance
Effective internal inductance
Certificates and approvals
CE conformity
Explosion protection
Types of protection
● Intrinsic safety "ia"
● Intrinsic safety "ic"
● Non-sparking "nA"
Permissible ambient temperature
7.5.7
External position sensing system
7.5.7.1
Operating conditions for all device versions
Ambient temperature
● Permissible ambient temperature for operation
Degree of protection
1)
Climate class
● Storage
● Transport
● Operation
) Impact energy max. 1 joule.
1
SIPART PS2 (6DR5...)
A5E03436620-04, 02/2014
Without Ex protection
1K5, but -40 to +90 °C (1K5, but -40 to +176 °F)
2K4, but -40 to +90 °C (2K4, but -40 to +176 °F)
3.5 mm (0.14"), 2 ... 27 Hz, 3 cycles/axis
98.1 m/s² (321.84 ft/s²), 27 ... 300 Hz, 3 cycles/axis
300 m/s
2.5 Nm (1.8 ft lb)
IP68 according to EN 60529; NEMA 4X / Encl. Type 4X
-
-
-
The applicable directives and standards applied with their revision levels can be
found in the EC declaration of conformity on the Internet.
Ex markings
ATEX/IECEx
Zone 1:
II 2 G Ex ia IIC T6/T4 Gb
Zone 2:
II 3 G Ex ic IIC T6/T4 Gc
Zone 2:
II 3 G Ex nA IIC T6/T4 Gc
T4: -40 ... +90 °C (-40 ... +194 °F)
T6: -40 ... +70 °C (-40 ... +158 °F)
With Ex protection
Ex "ia"
(984 ft/s
), 6 ms, 4000 shocks/axis
2
2
Metal
4.2 Nm (3.1 ft lb)
U
= 5 V
i
I
= 160 mA
i
P
= 120 mW
i
C
= 180 nF
i
L
= 922 μH
i
FM
IS, Class I, Divison 1, ABCD
IS, Class I, Zone 1, AEx ib, IIC
-
NI, Class I, Divison 2, ABCD
NI, Class I, Zone 2, AEx nA, IIC
T4: -40 ... +85 °C (-40 ... +185 °F)
T6: -40 ... +70 °C (-40 ... +158 °F)
In hazardous areas, observe the maximum permissible
ambient temperature corresponding to the temperature
class.
-40 ... +90 °C (-40 ... +194°F)
IP66 according to EN 60529 / NEMA 4X
According to DIN EN 60721-3-4
1K5, but -40 ... +90 °C (1K5, but -40 ... +194 °F)
2K4, but -40 ... +90 °C (2K4, but -40 ... +194 °F)
4K3, but -40 ... +90 °C (4K3, but -40 ... +194 °F)
With Ex protection
Ex "ic", "nA"
Stainless steel
4.2 Nm (3.1 ft lb)
U
= 5 V
i
C
= 180 nF
i
L
= 922 μH
i