4.2.1.2 Operation

The following chart describes functions and operations of these buttons and LEDs
Button/LED
Button 14
Inverter ON/OFF Button
Button 7
Site Wiring Fault E/D Button
Mute Buzzer (Alarm Reset)
Force the unit to bypass or
Button 6
Reset LCM Alarm (alarm which
indicates end of estimated
Show Output Load level
Button 5
Cold Start Enable/Disable
LED 1 (*)
Site Wiring Fault Detection LED
LED 2 (*)
LED 3 (*)
LED 4 (*)
LEDs 1, 2, 3
Battery Capacity Level / Output
& 4 (*)
Site Wiring Fault E/D LED
LED 8
LED 9
LED 10
LED 11
LED 12
LED 13
LED 15
(*) These LEDs show battery capacity level or output load level (depending on button 5) and normally they should be read
as a group. However, in case of certain events (SWF, Battery Fault, UPS Fault or UPS Overload), they pass to indicate it by
fl ashing and should be read individually.
Function
LED test
comeback
battery life)
Battery Fault LED
UPS Fault LED
UPS Overload LED
Load Level
Outlet 1 ON/OFF LED
Outlet 2 ON/OFF LED
Bypass Mode LED
Line Mode LED
Battery Mode LED
Inverter ON LED
Operation/Defi nition
Press one second to switch on/off the inverter
Press seven seconds to enable/disable Site
Wiring Fault detection
Press one second to mute the buzzer
Press for LED test (all LEDs fl ashing)
Press buttons 6 and 5 for four seconds to force
the unit to bypass or to return from bypass
Press buttons 6 and 5 for three seconds to
reset this alarm (if the alarm is active, it is
necessary to push these buttons 4 more
seconds to switch the unit to bypass, as per
above functionality)
Press to show output load level on LEDs 1, 2
3 and 4 (by default they show battery capacity
level)
Press fi ve seconds to enable/disable cold start
functionality
Indicates if Site Wiring Fault has been detected
Indicates if a battery fault has been detected
Indicates if a UPS fault has been detected
Indicates if an output overload has been
detected
Indicates battery capacity level (by default), or
output load level if button 5 is pressed
Indicates if Site Wiring Fault detection is enabled
or disabled (enabled: ON; disabled: OFF)
Indicates if group 1 of the output controllable
sockets is supplying power or not (supplying
power: ON; not supplying power: OFF; status
change in progress: fl ashing)
Indicates if group 2 of the output controllable
sockets is supplying power or not (supplying
power: ON; not supplying power: OFF; status
change in progress: fl ashing)
Indicates if the unit is on bypass mode (fl ashing)
Indicates if the unit is on line mode (ON)
Indicates if the unit is on battery mode (ON)
Indicates if the inverter is ON or OFF
Chloride Active
UK
19