13. Troubleshooting

Problem
Unit wonʼt start or starts but will not
run.
Unit starts, but engine has low
power.
Engine hesitates.
No power under load.
Runs erratically.
Smokes excessively.
28
04.05.2007
15:17 Uhr
Seite 28
Probable cause
Incorrect starting procedures.
Incorrect carburetor mixture
adjustment setting.
Fouled spark plug.
Fuel filter plugged.
Incorrect lever position on choke.
Dirty spark arrester screen.
Dirty air filter.
Incorrect carburetor mixture
adjustment setting.
Incorrect carburetor mixture
adjustment setting.
Incorrectly gapped spark plug.
Incorrect carburetor mixture
adjustment setting.
Incorrect fuel mixture.
Corrective Action
Follow instructions in the User
Manual.
Have carburetor adjusted by an
Authorized Service Center.
Clean / gap or replace plug.
Replace fuel filter.
Move to RUN position.
Replace spark arrester screen.
Remove, clean and reinstall filter.
Have carburetor adjusted by an
Authorized Service Center.
Have carburetor adjusted by an
Authorized Service Center.
Clean / gap or replace plug.
Have carburetor adjusted by an
Authorized Service Center.
Use properly mixed fuel (40:1
mixture).