OF 40)
8.4.3
Option #3 - Raised Base Installation of More Than 4"
D
D
E
D
D
A clearance of 80" (2.03 m) (A) between the base of the fireplace and the ceiling must be respected.
8.4.4

Floor Protection

Option Installation type
#1
On floor level
#2
Raised base of 4" or less
#3
Raised base of more than 4"
Regardless of the installation type, there must be at least 8" (203 mm) on each side of the
fireplace door opening (C). The joint between the hearth extension and the fireplace must be
protected by a metal sheet not supplied.
Floor
protection
noncombustible surface such as ceramic, concrete
board, brick or other equivalent material approved
as floor protection. If the ceramic is used, it must
be placed on a continuous non-combustible panel
to prevent spills from being brought into contact
with the floor through cracks or gaps in the ceramic
slurry. Alternatives approved by the local building
code may also be used.
Do not leave carpets under the floor protection.
WFP-75 8411
Stove Builder International Inc. | 46345 | Rev: Apr 13 2020 12:33PM | Uncontrolled Copy
A
F
E
R factor
required
Yes (1.00)
Yes (1.00)
No
must
be
a
continuous
When the fireplace is installed on a raised
base of more than 4" (E), a non-combustible
floor protection of at least 16" (A) with an R
factor of 1.00 must be installed in front of the
fireplace.
The upper and lower angle, for the full width
of the floor protection, must be protected by
2" horizontally and vertically (E) by a folded
and continuous metal sheet (D = 2" [51 mm])
(not supplied). The sheet metal does not have
to cover the rest of the wall between the base
of the fireplace and the floor.
A
B
41 ½"
16"
(406 mm)
(1054 mm)
41 ½"
16"
(406 mm)
(1054 mm)
41 ½"
16"
(406 mm)
(1054 mm)
C
A
C
8"
(203 mm)
8"
(203 mm)
8"
(203 mm)
B
Page 23