HearthStone WFP-75 8411 Manuel D'installation Et D'utilisation page 115

Table des Matières

Publicité

Les langues disponibles

Les langues disponibles

Report prepared for Guillaume Thibodeau-Fortin (Stove Builder International Inc.) on
6/8/2020 7:48:41 AM
103704002MTL-001 TEST REPORT REV 4
TEST REPORT FOR STOVE BUILDER INTERNATIONAL INC.
Report No.: 103704002MTL-001
Date: 11/16/18
TABLE 3 – DILUTION TUNNEL FLOW RATE MEASUREMENTS AND SAMPLING DATA
RUN
#
1
2
3
TABLE 4 - DILUTION TUNNEL DUAL TRAIN PRECISION
RUN
#
1
2
3
TABLE 5 - GENERAL SUMMARY OF RESULTS
RUN #
1
2
3
*Data including the cold-Start
TABLE 6 - CSA B415.1 RESULTS
BURN RATE
(kg/hr)(dry)
Low – 1.1
Medium – 1.4
High – 3.8
Version: 05/10/17
Stove Builder International Inc. | 46345 | Rev: Apr 13 2020 12:33PM | Uncontrolled Copy
BURN
VELOCITY
VOLUMETRIC
TIME
(ft/sec)
FLOW RATE
(min)
(dscf/min)
400
18.93
371.51
140
19.13
360.16
330
18.50
367.61
SAMPLE RATIOS
TOTAL EMISSIONS (g)
TRAIN 1
TRAIN 2
TRAIN 1
2339
2348
5.614
2557
2542
6.137
2309
2314
3.464
BURN RATE
Change
(kg/hr)(dry)
in
(OVERALL)
Surface
Temp
O
(
F)
1.1
222
3.8
400
1.4
221
CO
EMISSIONS
EFFICIENCY (% HHV)
(g/min)
1.1
1.1
0.8
AVG TEMP
SAMPLE
(°R)
VOLUME (dscf)
1
552
63.528 63.302
573
19.720 19.839
555
52.527 52.423
DEVIATION (%)
TRAIN 2
5.399
1.95%
6.354
1.74%
3.934
6.35%
INITIAL DRAFT
RUN TIME
(in/H
O)
(min)
2
0.054
400
0.001
140
0.059
330
HEATING
Heating
Efficiency
(% LHV)
69%
74%
68%
73%
67%
73%
Page 18 of 21
(18 OF 21)
1829, 32nd Avenue
Lachine, Que,H8T 3J1
Telephone: 514-631-3100
Facsimile: 514-631-1133
www.intertek.com/building
PARTICULATE
CATCH (mg)
2
1
2
2.4
2.3
2.4
2.5
1.5
1.7
DEVIATION (g/kg)
0.49%
0.43%
1.59%
AVERAGE DRAFT
(in/H
O)
2
0.045
0.063
0.052
HEAT OUTPUT
(Btu/hr)
14,222
17,712
48,185
GFT-OP-10c
Page 794 of 971

Publicité

Chapitres

Table des Matières
loading