Report prepared for Guillaume Thibodeau-Fortin (Stove Builder International Inc.) on
6/8/2020 7:48:41 AM
103704002MTL-001 TEST REPORT REV 4
TEST REPORT FOR STOVE BUILDER INTERNATIONAL INC.
Report No.: 103704002MTL-001
Date: 11/16/18
SECTION 10
TEST RESULTS
DESCRIPTION OF TEST RUNS:
RUN #1 (November 1
with a category "Low burn rate" of 1.1 kg/hr. Let the door ajar for 3.5 minutes, and then closed.
The air control was opened for 10 minutes which is when 15% of the load weight has been
consumed, and then set at the targeted burn rate. The fan was turned on at low speed at 30
minutes.
RUN #2 (November 2
category High burn rate of 3.8 kg/hr. The door was open for 5 minutes, then closed. The air
control was fully opened. Start the fan at full speed.
RUN #3 (November 3
minutes with a category "Medium burn rate" of 1.4 kg/hr. Let the door ajar for 3.5 minutes, and
then closed. The air control was opened for 9 minutes which is when 15% of the load weight has
been consumed, and then set at the targeted burn rate (1/4" open). The fan was turned on at
medium speed at 30 minutes.
TABLE 1 – EMISSIONS
RUN#
1
2
3
*Data including the cold-Start
TABLE 2 – TEST FACILITY CONDITIONS
RUN
#
1
2
3
Version: 05/10/17
Stove Builder International Inc. | 46345 | Rev: Apr 13 2020 12:33PM | Uncontrolled Copy
st
, 2018) Air control set at the lowest burn rate, burn time was 400 minutes
nd
, 2018) Air control set fully opened, burn time was 140 minutes with a
rd
, 2018) Air control set at the targeted burn rate, burn time was 330
TEST
BURN RATES
PARTICULATE
DATE
(kg/hr)(Dry)
EMISSION
RATE (g/hr)
Nov. 1st
1.1
2018
Nov. 2nd
2.9*
2018
Nov. 5th
1.4
2018
ROOM
ROOM
BARO
TEMP
TEMP
PRES
BEFORE
AFTER
BEFORE
(°F)
(°F)
(in/Hg)
70
75
29.9
68
77
29.8
68
73
30.5
st
1
HOUR
CO EMISSIONS
EMISSIONS
(g)
0.83
2.58
2.68
2.63
0.67
2.55
BARO
R. H.
R. H.
PRES
BEFORE
AFTER
AFTER
(%)
(%)
(in/Hg)
29.9
41
35
29.8
41
30
30.4
35
30
Page 17 of 21
(17 OF 21)
1829, 32nd Avenue
Lachine, Que,H8T 3J1
Telephone: 514-631-3100
Facsimile: 514-631-1133
www.intertek.com/building
HEATING
(g/min)
EFFICIENCY
(%HHV)
1.1
69%
0.8
67%
1.1
68%
AIR VEL
AIR VEL
BEFORE
AFTER
(ft/min)
(ft/min)
0
0
0
0
0
0
GFT-OP-10c
Page 793 of 971