HearthStone WFP-75 8411 Manuel D'installation Et D'utilisation page 30

Table des Matières

Publicité

Les langues disponibles

Les langues disponibles

Report prepared for Guillaume Thibodeau-Fortin (Stove Builder International Inc.) on
6/8/2020 7:48:41 AM
MANUAL INSTALLATION AND OPERATION WFP-75 8411 ENGLISH
OF 40)
8.3.1
Fireplace Framing
D
8.3.2
Framing with Fresh Air Intake
If a finishing material is installed inside the enclosure, its thickness must be added to the following
measurements.
The framing can be constructed of combustible materials.
J : Distance between framing and side fireplace standoff 12" (305 mm)
K : Framing width (Installation with centered fireplace) 61 ¾" (1568 mm)
L : Fresh air intake duct
9
Framing dimensions are for reference only. These measurements are recommended to prevent the ducts from being inside the standoff or have too
tight duct curves. Smaller dimensions can be used depending on the size and type of duct as well as the configuration of the installation.
HVAC duct, as per ULC S110 or UL 181, class 0 or class 1, must withstand temperatures up to 250oF.
10
Page 20
Stove Builder International Inc. | 46345 | Rev: Apr 13 2020 12:33PM | Uncontrolled Copy
Framing dimensions should be used as a reference
only
If a finishing material is installed inside the enclosure,
its thickness must be added to the following
measurements.
The framing can be constructed of combustible
materials.
A : Framing width 37 ¾" (960 mm)
B : Framing height to the first header 44 ⅛" (1045
mm)
B
C : Framing depth 22 ⅛" (562 mm)
D : Framing total height 80" (2032 mm)
C
A
9
.
10
WFP-75 8411
Page 709 of 971
(20

Publicité

Chapitres

Table des Matières
loading

Table des Matières