HearthStone WFP-75 8411 Manuel D'installation Et D'utilisation page 118

Table des Matières

Publicité

Les langues disponibles

Les langues disponibles

Report prepared for Guillaume Thibodeau-Fortin (Stove Builder International Inc.) on
6/8/2020 7:48:41 AM
103704002MTL-001 TEST REPORT REV 4
TEST REPORT FOR STOVE BUILDER INTERNATIONAL INC.
Report No.: 103704002MTL-001
Date: 11/16/18
SECTION 13
REVISION LOG
REVISION #
0
1
2
2
3
4
Version: 05/10/17
Stove Builder International Inc. | 46345 | Rev: Apr 13 2020 12:33PM | Uncontrolled Copy
DATE
PAGES
11/16/18
N/A
08/05/2019
1, 16, 19
P17-18 (Table
02/24/2020
1and 6)
02/24/2020
3
02/24/2020
19(Table 7)
04/06/220
1,3, 16, 19
Page 21 of 21
(21 OF 21)
1829, 32nd Avenue
Lachine, Que,H8T 3J1
Telephone: 514-631-3100
Facsimile: 514-631-1133
www.intertek.com/building
REVISION
Original Report Issue
Addition of models: FP10 LAFAYETTE IIS,
WFP-75 8411 to the existing series 2.5
From 0.8 g/min to 1.1 g/min
Changed de CO Emissions from 0.88 to 1.05
Changed KxCO (G/h 0.040, 0.32, 0.88 to
0.44, 0.45, 1.05
Addition of the name of the model tested.
GFT-OP-10c
Page 797 of 971

Publicité

Chapitres

Table des Matières
loading