Technical Specification; General Safety Warnings - EUROM PAC 120 Manual D'instructions

Table des Matières

Publicité

Les langues disponibles

Les langues disponibles

Technical specification

Type
Cooling capacity
Max. power usage
Air displacement max
Connected power
Cooling fluid
Class of insulation
Noise level
Fan settings
Operating temperature
Fuse
Waste pipe
Weight
Dimensions
Safety Warnings
Read all safety warnings and other instructions. Failure to follow all
instructions can cause injury or material damage.

General safety warnings

1. This unit is exclusively intended for household use.
2. A mobile air conditioner needs air to be able to discharge heat to
the outside!
3. Therefore, never use a mobile air conditioner in an airproof room.
Always make sure there is sufficient ventilation. Without sufficient
ventilation, a vacuum is created in an airproof room, while a mobile
air conditioner is operating, and this vacuum can disrupt the safe
operation of geysers, extractors, mechanical ventilation systems,
ovens, fireplaces and gas heaters. The vacuum can cause the
exhaust gases, which these appliances usually discharge to the
outside, to wind up either partially or entirely in the room.
4. Always ensure (even during transport!) that the unit remains
upright. If the unit has been lying on its side, wait 2 hours before
using. This time is required in order for the compressor to function
correctly.
5. Ensure that the unit is always placed on a sturdy, flat and
horizontal surface.
PAC 120
12000 Btu/uur (3400 W) 14000 Btu/uur (3800 W)
1346 W
Sound power level 65dB(A)
Sound pressure level 55dB(A)
30 kg
71,5 x 33,5 x 44 cm
36
380 m³/uur
220-240V~50Hz
R290/226g
IPX0
2
18-35°C
F, 250V AC, 2A
Ø 150 mm
PAC 140
1538 W
31 kg

Publicité

Table des Matières
loading

Ce manuel est également adapté pour:

Pac 140381016381023

Table des Matières