5
Diagnosis
5.1 Display of the Mod/Net LED
LED
Operating status
lights up
Normal; the SPC200 is
green
online and is connected to a
communication partner.
is off
The bus interface of the
SPC200 is not supplied
with current.
The SPC200 does not
recognize any communi
cation on the bus.
flashes
The SPC200 is ready for
green
data exchange and is online
on the bus. However, there
is no communication
connection to a master. It is
possible that the SPC200 is
not yet assigned to a
master.
flashes
Fault can be rectified
red
The SPC200 has recog
nized Communication−
Time−Out.
The SPC200 has not been
addressed for a long time
(Time−Out time).
Festo SPC200−COM−DN2 0602a English
Fault treatment
None
S Check the power supply
to the bus interface/
internal logic.
S Check the physical con
nection to the bus and
the terminating resistor.
S Complete the configura
tion. Check/correct the
Scan List of the relevant
master.
S Physical bus connection
interrupted.
Check master for ability
to communicate.
S Reset the Time−Out
status of the SPC200 by
new allocation. Connect
the SPC200 to the bus
again.