DESCRIPTION
The Serene fan is a continuously running extract fan for kitchens, utility rooms,
bathrooms and toilets.
The product incorporates an airflow detection system that detects the installation duct
resistance and maintains the correct fan speed to achieve the preset extract flow rate
of either 6l/s, 8l/s or 13l/s, minimising energy use and noise (see Section C-Setup for
more information).
The incorporated LED display allows the installer to verify the installed flow rate, and
also provides feedback for system pressure and days installed (for landlords).
The fan can be wall or panel/ceiling mounted.
A. INSTALLATION
PANEL/CEILING MOUNTING
1.
Cut a 105mm diameter hole.
2.
Remove the front panel by carefully pulling away from the fan.
3.
Loosen the two self-retaining screws and remove the inner grille by carefully
pulling away from the housing.
4.
Mark the screw centres through the holes in the fan back plate. Drill, plug and
screw into position. Attach ducting as required for the installation.
5.
Wire the fan as described in Section B-Wiring. Adjust any settings as required
(see Section C-Setup).
6.
After installation, ensure impeller rotates freely.
7.
Replace the inner grille and tighten the retaining screws. Replace the front
panel.

WALL MOUNTING

1.
For wall mounting cut a 117mm diameter hole through the wall and insert the
wall sleeve. Slope the sleeve slightly downwards away from the fan. Where
necessary cut to length and cement both ends into position flush with the wall
faces.
2.
Fix exterior grille into position with the louvres positioned downwards.
3.
Remove the front panel by carefully pulling away from the fan.
4.
Loosen the two self-retaining screws and remove the inner grille by carefully
pulling away from the housing.
5.
Mark the screw centres through the holes in the fan back plate. Drill, plug and
screw into position.
6.
Wire the fan as described in Section B-Wiring. Adjust any settings as required
(see Section C-Setup).
7.
After installation, ensure impeller rotates freely.
8.
Replace the inner grille and tighten the retaining screws. Replace the front
panel.