Using the wood burning stove

Adjustment of the air damper - the damper has 3 settings
Position 1
The damper is almost closed meaning that there is a minimal air intake.
Position 2
Pull the lever until first click. This position gives full secondary air.
During normal stoking the lever is set between position 1 and 2.
When the flames are clear and yellow, the damper is set correcly, i.e. resulting in a slow/
optimal burning.
Position 3
Pull the lever until next click.
The air damper is completely open and gives full primary and secondary air.
The position is for the lighting stage and is not used under normal operation.

Control

If the ash is white and the walls in the combustion chamber sott-free after the stove has
been used, the air regulation was set correctly and the wood was sufficiently dry.