5.8
Mounting with cable gland (PG 9)
DAMAGE TO THE SYSTEM
Only use existing tank connections to install the product.
Verify that you only drill into existing screw fittings, caps or blind connections.
Verify that no foreign matter (such as drilling chips) can get into the tank dur-
ing mounting.
Failure to follow these instructions can result in equipment damage.
A
Mounting
NOTICE
1. Remove the screw fitting (B), the
cap/blind connection from the
tank and drill a Ø 15 mm hole.
2. Insert the enclosed cable gland
(PG 9) (A) and fasten it with the
enclosed nut.
B
3. Route the cable of the pressure
sensor trough the cable gland (PG
9) (A) and tighten the cable gland
so that the cable can no longer be
moved and that the connection is
odour-tight.
EN
20
DIT 10