5.4.2
Connecting the lithium battery
If you insert a new lithium battery, the tank data already stored are not
cleared.
INOPERABLE PRODUCT
•
Verify correct polarity when plugging the battery connector into the socket on
the PCB.
Failure to follow these instructions can result in equipment damage.
Mounting
NOTICE
1. Turn the upper part of the control
unit clockwise all the way to the
stop.
2. Remove the upper part of the
A
housing.
- There are wires between the
B
3. Press the reset pushbutton (A)
and hold it down.
4. Plug the two-pin battery connector
into the two-pin socket (B) on the
PCB.
- Verify correct polarity.
5. Release the reset pushbutton (A).
upper part of the housing and the
bottom part of the housing.
DIT 10
EN
14