4.5.2
Submersible probe
Parameter
General specifications
Dimensions (Ø x L)
Weight
Cable length
Pressure range
Measuring accuracy*
Temperature error
Ambient conditions
Temperature of the medium
Ambient temperature storage
Electrical safety
Degree of protection (EN 60529)
*Accuracy of the complete system with reference to the indication of the liquid level in mm: ±1.5 % FSO,
IEC 60770.
Product description
Value
24 x 64.5 mm
350 g
6 m
0 - 400 mbar
< ± 0.5 %
< ± 0.3 % FSO, 10 K
in compensated range 0 ... 70 °C
-5 ... 70 °C
-5 ... 70 °C
IP 68
EN
10