6.1.3
Tank height
Verify that the arrow at the bottom of the display points to the unit %.
The display shows the tank height adjusted.
- The value 0000 means that no tank height has yet been entered.
1. Use the two programming keys to enter the determined tank height in
mm.
2. Press the programming key (arrow up) to select the digit to be changed.
3. Press the programming key (arrow down) to change the value of the
selected digit.
4. Press the function key to confirm the setting.
6.1.4
Current liquid level
Verify that the arrow at the bottom of the display points to the unit Level
(FH).
- The display shows level measured by the submersible probe in mm.
The value shown on the display is based on the tank data you have
already entered and on the measurement.
Check whether the displayed value corresponds to the value you have
determined in chapter "Determining the tank data". The fuller the tank, the
higher the measuring accuracy.
- If the actual liquid level is less than 50 %, it is not meaningful to correct
the displayed value.
1. Use the two programming keys to enter the determined liquid level in
mm.
2. Press the programming key (arrow up) to select the digit to be changed.
3. Press the programming key (arrow down) to change the value of the
selected digit.
4. Press the function key to confirm the setting.
You have now entered all the tank data and the control unit switches to
measurement mode.
- The symbol (both arrows) is no longer displayed in the top left corner of
the display.