Operating Instructions SATAjet 100 B F (RP / HVLP), B P
■ Remove the air piston with air piston spring [10-5].
■ Remove the air piston rod [10-3].
■ Screw the self-adjusting seal [10-2] out of the gun body.
Mount self-adjusting seal
■ Screw in the self-adjusting seal [10-2].
■ Insert the air piston rod [10-3] in the correct position.
■ Insert air piston with air piston spring [10-5] and air micrometer [10-4]
and grease with SATA high performance grease (# 48173).
■ Press the air micrometer [10-4] into the gun body.
■ Screw in the locking screw [10-1].
■ Mount the trigger guard [9-2].
■ Insert spring and paint needle [9-1].
■ Screw adjusting screw [1-3] with counter nut [1-4] into the gun body.
After installation, adjust the material flow according to chapter 8.2.
9.6. Replace spindle of round / flat fan control
Replacement is necessary if air escapes from the round / flat fan control or
if it is no longer possible to adjust the spray fan pattern.
Dismantle spindle
■ Unscrew the countersunk screw [11-2].
■ Remove the control knob [11-3].
■ Screw spindle [11-4] out of the gun body using the SATA universal
spanner.
Mount the spindle
■ Screw the spindle [11-4] into the gun body using the SATA universal
spanner.
■ Position the control knob [11-3].
■ Coat the countersunk screw [11-2] with Loctite 242 [11-1] and screw
handtight.

10. Care and storage

Careful handling together with constant care of the product is necessary
to ensure that the spray gun functions properly.
■ Store the spray gun in a dry place.
■ Clean the spray gun thoroughly every time after it has been used and
every time before changing the material.