PRECAUTIONS (cont...)
1 - GENERAL REMARKS (cont...)
- Before applying any aggressive
chemicals, please consult your dis-
tributor to confirm compatibility
with the dosing pump.
- All assembly should be done
without tools, hand tighten only.
2 - WATER WITH HIGH PARTICLE
CONTENT
- A (ex.: 300 mesh - 60 microns depen-
ding on your water quality) water
filter must be installed upstream from
the DOSATRON (see accessories), if a
filter is not installed abrasive substan-
ces will cause the DOSATRON to
deteriorate prematurely.
3 - WATER-HAMMER / EXCESSIVE
FLOW
- For installations subject to water
hammer a protection device such as
a check valve or union ball check
must be fitted (pressure/flow
control system).
- For automatic installations, slow
opening and closing solenoid valves
are preferable.
- In an installation where a
DOSATRON serves several sectors, the
closing of one sector and the opening
of another sector must be done at the
same time (simultaneous operation of
the solenoid valves).
©
DOSATRON INTERNATIONAL / 36
4 - INSTALLATION LOCATION
- The location of the DOSATRON and
concentrate container should be
accessible, but should never present
a risk of pollution or contamination.
- It is recommended to label all
water lines with a warning about
the injected solution i.e. Not For
Human Consumption.
5 - MAINTENANCE
- Rinse the injection areas after using
the DOSATRON. To do this, insert suc-
tion tube into a container of clean
water and inject about 1/4 liter
[8 1/2 US Fl.oz].
- Routine maintenance once a year
will add to the life of your DOSATRON.
Change the dosing seals at least once
a year, depending on its use.
6 - SERVICE
- This DOSATRON was tested prior to
packaging.
- Complete maintenance and seal
kits are available.
- Call your DOSATRON distributor for
service or parts.

ASSEMBLING THE DOSATRON

ASSEMBLY SHOULD BE CARRIED
OUT WITHOUT THE USE OF TOOLS
The DOSATRON is delivered with :
- a mounting bracket,
- a suction tube with a strainer.
The bracket enables the DOSATRON
to be fixed to
a wall.
A
Fig. 1
C
The DOSATRON is delivered with a suction tube (cut it to the needed
length) enabling its use with a large capacity concentrate container.
The tube must be fitted with its strainer and weights.
The instructions for fitting the tube are to be found in the specific chapter.
NOTE : The maximum suction height is 4 meters (13 vertical feet).
Fit the tube, equipped with its strainer and its weight, and immerse it in the
solution to be injected.
©
DOSATRON INTERNATIONAL / 37
Snap the DOSATRON into the
bracket by fitting the two lugs on
one side of the body (Fig. 1-A) into
the corresponding holes in the
bracket (Fig. 1-B), and springing the
bracket arms apart until the other 2
lugs click into place.
B
Remove the plastic caps (Fig. 1-C)
which block the inlet and outlet of
your DOSATRON before connecting
to the water supply.
The DOSATRON can be connected
to the water supply by means of
Ø 20 x 27 (3/4") bore flexible hose
and hose tail fittings with hose clips.
Make certain that the water flows in
the direction of the arrows on the
motor body.