  • FR

Les langues disponibles

  • FRANÇAIS, page 26
3.

Setup

3.1

Attaching the Tip to the Gun

1. Lock the trigger by rotating the trigger lock forward until it
stops.
2. Attach tip guard and tip to the gun as instructed by the tip
guard or tip manuals.
POSSIBLE INJECTION HAZARD. Do not spray
without the tip guard in place. Never trigger the
gun unless the tip is in either the spray or the unclog
position. Always engage the gun trigger lock before
removing, replacing or cleaning tip.
3.2
Checking the Outlet Valve (optional)
of the pump housing to make sure the outlet ball valve moves
freely.
3.3

Attaching the Paint Hose

wrench to tighten the paint hose securely.
2. Attach the spray gun to the other end of the high pressure
hose. Tighten the hose securely to the gun using two
wrenches.
3. Plug the sprayer into a properly grounded outlet or heavy
duty grounded extension cord.
ED655
1
GB
Do not use more than 100 feet of cord. If you must
i
spray a long distance from a power source, use
more paint hose, not more extension cords. Use a
minimum size of 16 gauge extension cord for up to
50 feet in length, or 12 to 14 gauge for extension
cords between 50 and 100 feet in length.
3.4

Preparing to Prime

1. Fill the inlet valve with water or with a light household oil.
the lowest pressure setting.
2
1
4. Increase the pressure by turning the pressure control knob
clockwise 1/2 turn.
5. Force the inlet valve to open and close by pushing on it with
a screwdriver or the eraser end of a pencil. It should move up
and down about 1/16 of an inch. Continue until water or oil
is sucked into the sprayer. This will wet the moving parts and
break loose any old paint residue.
6. Put the palm of your hand over the inlet. Turn the pressure
feel suction coming from the inlet valve. If you do not, see the
section on cleaning and servicing the outlet valve.
7. Turn the pressure control knob counterclockwise to the
minimum pressure setting.