Fig. 4: Transporting the motor
4

Intended use

Purpose
Fields of application
Contraindications
5

Product information

5.1

Type key

26
WARNING! Risk of injury due to the weight of the pump!
The pump itself and pump parts can be extremely heavy. Falling
parts pose a risk of cuts, crush injuries, bruises or impacts, which
may lead to death.
• Always use suitable lifting equipment and secure parts against fall-
ing.
• Never stand underneath a suspended load.
• Wear protective clothing for all work (safety shoes, helmet, pro-
tective gloves and protective goggles).
The glanded pumps from the series IPL (inline), DPL (double) are used
as circulation pumps in the fields of application named in the follow-
ing.
They may be used for:
• Hot-water heating systems,
• Cooling and cold water circulation systems,
• Industrial circulation systems,
• Heat carrier circuits.
Typical installation locations are technical rooms within the building
with other domestic installations. Installing the device directly in
other used rooms (residential and work rooms) is not intended.
CAUTION! Risk of material damage!
Unpermitted substances in the fluid can destroy the pump. Abra-
sive solids (e.g. sand) increase pump wear.
Pumps without an Ex rating are not suitable for use in potentially
explosive areas.
• The intended use includes complying with these instructions.
• Any other use is considered to be outside the intended use.
The type key consists of the following elements:
Example:
IPL 50/175-7.5/2
IPL
Flange-end pump as Inline pump
DPL
Flange-end pump as Double pump
50
Nominal diameter DN of the pipe connection [mm]
170
Nominal impeller diameter [mm]
7.5
Rated power P
2
Number of poles
P2
Standard version variant:
Potable water approval acc. to ACS
(see www.wilo.com)
K1
Standard version variant:
Outdoor installation "Western European climate"
(motor with protective fan cover)
K4
Standard version variant:
Outdoor installation "Western European climate"
(motor with protective fan cover, additional standby
heating 1~230 V)
K3
Standard version variant:
3 PTC thermistor sensors
[kW]
2
WILO SE 11/2017