Presence Function; Verifying The Values Set For Each Parameter Using The Transmitter; Adding Or Removing Devices; Memorising Additional Devices - Nice Filo400 Instructions Et Avertissements Pour L'installation Et L'utilisation

Table des Matières

Publicité

Les langues disponibles

Les langues disponibles

Parameters
Value
Pause time
10 sec
20 sec *
40 sec
60 sec
Pedestrian
Gate open to 0.7 m
opening
Gate open to 1 m *
Gate halfway open
Gate 3/4 open
Motor force
Low
Medium-low *
Medium-high
High
Step-by-Step
Open - Stop - Close - Stop
(SbS)
Open - Stop - Close - Open *
function
Open - Close - Open - Close
Opening only
OGI (Open Gate
OGI *
Indicator)
30 sec courtesy light
function
60 sec courtesy light

Presence function

* Factory value
9.1.2 - Presence function
This function is regulated by key T5 of the ECCO5... transmitter (Fig. in Table 4) and determines the operating mode of the OGI output. If LM100 lighting
modules (not supplied) are connected to this output, this function operates as follows:
- with the gate closed: when an opaque object interrupts transmission (infrared) of the photocells, the courtesy light switches on for 5 seconds. After
5 seconds, if the transmission is still interrupted, the courtesy light switches on for another 5 seconds; if instead the photocell does not detect any
object, the courtesy light switches off.
- with the gate moving (opening and closing manoeuvre): the courtesy light is always lit. At the end of the manoeuvre (opening or closing) it re-
mains lit for a further 5 seconds.
- with the gate open and automatic closing not active: at the end of the manoeuvre the courtesy light remains lit for 5 seconds then switches off
and follows the gate's behaviour when closed.
- with the gate open and automatic closing active: at the end of the manoeuvre the courtesy light remains lit for 5 seconds then switches off and
follows the gate's behaviour when closed.
If the OGI function is active, the lamp connected to it behaves in the following way:
- off: automation in fully closed position.
- slow flashing: execution of the opening manoeuvre.
- fast flashing: execution of the closing manoeuvre.
- steady lit: automation in fully open position.
9.1.3 - Verifying the values set for each parameter (using the transmitter memorised in mode 1)
The check can be effected by means of any transmitter memorised in Mode 1 (as those supplied, see Paragraph 9.3.1). If there is no transmitter memo-
rised in Mode 1, it is possible to memorise one solely for programming purposes then cancelling it (see Paragraph 9.4).
Adjustment procedure (before proceeding check the parameter to be verified in Table 3 and the action to be performed):
01. On the transmitter (Fig. 24) simultaneously press and hold buttons T1 and T2 for 5 seconds then release them.
02. Within 3 seconds from releasing them, perform the action specified in Table 3 to verify the desired parameter.
03. Release the key when the flashing light starts flashing: count the flashes. Check in Table 2 the value corresponding to the number of flashes.
TABLE 3
Parameters
Actions to be performed
Pause time
Press and hold key T1
Pedestrian opening
Press and hold key T2
Motor force
Press and hold key T3
SbS function
Press and hold key T4
OGI function
Press and hold key T5

9.2 - ADDING OR REMOVING DEVICES

It is possible to add or remove devices at any time to the system: if devices are added, it is important to verify that these are perfectly compatible with
FILO 400C/FILO 600C; for further details contact the Nice technical support service.

9.2.1 - Memorising additional devices

The recognition operation of the devices connected to the ECSBus and to the Stop input is usually carried out during the installation phase; but if devi-
ces are added (or removed) subsequently, the following procedure must be carried out:
TABLE 2
No. of flashes emitted by
Transmitter key to be
the flashing light
used
T1
1
2
T1
3
T1
4
T1
1
T2
T2
2
T2
3
4
T2
1
T3
2
T3
3
T3
T3
4
T4
1
2
T4
3
T4
4
T4
1
T5
T5
2
T5
3
4
T5
Actions to be performed
Press T1 once
Press T1 twice
Press T1 three times
Press T1 four times
Press T2 once
Press T2 twice
Press T2 three times
Press T2 four times
Press T3 once
Press T3 twice
Press T3 three times
Press T3 four times
Press T4 once
Press T4 twice
Press T4 three times
Press T4 four times
Press T5 once
Press T5 twice
Press T5 three times
Press T5 four times
24
1
English – 10
2

Publicité

Table des Matières
loading

Ce manuel est également adapté pour:

Filo400startFilo600Filo600startFilo serie

Table des Matières