LED status displays

9
Diagnostics
LED status displays
0
EMF2178IB
Address
Bd
6
L
CANopen
5
Pos.
Status display (LED)
0
Connection status to standard device, two−colour LED (green/red)
OFF
GREEN
Blinking
Constantly ON
RED
Constantly ON
Blinking
78
1
2
3
4
2178
Description
l
The communication module is not supplied with voltage.
l
The external voltage supply is switched off.
The communication module is supplied with voltage, but has
no connection to the standard device.
Cause:
The standard device is ...
l
switched off;
l
in the initialisation phase;
l
not available.
The communication module is supplied with voltage and is
connected to the standard device.
CANopen operation impossible.
Permanently:
l
Parameters are reset to Lenze setting.
l
CANopen operation possible.
1 x blinking:
l
An error occurred while saving a value.
2 x blinking:
l
CANopen operation possible.
l
The node address/baud rate from C1850/C2350 or
C1851/C2351 could not be accepted .
l