Technical data

7.3
P.02: Unit for temperature display
The system can display the room temperature in °C or °F. This parameter can be
configured:
➤ Switch to configuration mode (chapter "Entering and exiting configuration
mode" on page 12).
✓ The display shows "P.01" and the symbol
➤ Press the
✓ The display shows "P.02" and the symbol lights up.
➤ Press the
✓ The code for the current setting is displayed:
– 0: °C
– 1: °F
➤ Use the
➤ Press the
✓ The set value is saved and is then applied when the system is restarted.
✓ You are then returned to the menu and can select another menu item by
pressing the
8
Technical data
Ref. number:
24 V
24 V 0°
Cooling capacity:
Rated input voltage:
Max. current consumption:
Operating temperature range:
Low voltage shutdown:
Noise emission:
Dimensions (L x B x H):
Weight:
14
or
button to select the menu item P.02.
button to change the setting.
or
button to select the desired temperature unit.
button to save the setting.
or
button.
Configurable (chapter "P.01: Low voltage shut-
CoolAir RTX1000, RTX2000
flashes.
CoolAir
RTX1000
9105306210
1200 W
24 Vg (20 Vg – 30 Vg)
5 – 25 A
+5 to +52 °C
down" on page 13)
< 70 dB(A)
645 x 860 x 308 mm
approx. 23 kg
RTX2000
9105306212
2000 W
5 – 29 A
approx. 32 kg