8.

Troubleshooting

The electrical supply must be disconnected via the installation's main
breaker or by disconnecting the plug before any work can be carried out.
The light does not work
Switch off power. Remove the 2 half rings and pull the glass of the DISC
downwards. You can now access the halogen bulb. Verify it is well-seated
and not broken. If you need to replace the bulb, replace it with a standard R7S
78mm, 240V/120W bulb.
Please note: Always use a cloth or gloves to replace the bulb, as touching it
with hands shortens the life considerably.
If this does not resolve your issue, verify that wires 5 and 6 are properly
inserted into the connection block. Refer to Steps 18 and 19. If problem persists,
reprogram the remote (See next page).
No heat
None of the elements are heating. Ensure power is set to HIGH. Verify that
wires 1, 2, 3 and 4 are properly connected (See Steps 18 and 19).
Only some elements are heating
If elements are not working, see Steps 18 and 19 and verify that wires 1, 2, 3
and 4 are securely connected in the proper terminals.
Nothing works
Verify the fuse in rear of control box is not blown. If blown, replace with
20A, 6.3 x 32mm, T slow rated 250VAC glass fuse.
Verify
all
wires
are
properly
inserted
in
the
connector
block
(See Step 19).
Verify that the circuit breaker switch is not tripped/is turned off.
Close the control box and retry.
If still not working, please contact your dealer.