Troubleshooting - Heatsail DISC Manuel D'utilisation

Table des Matières

Publicité

Les langues disponibles

Les langues disponibles

EN
7.

Troubleshooting

The electrical supply must be disconnected via the installation's main
breaker or by disconnecting the plug before any work can be carried out.
The light does not work
Switch off power. Remove the 2 half rings and pull the glass of the DISC
downwards. You can now access the halogen bulb. Verify it is well-seated
and not broken. If you need to replace the bulb, replace it with a standard R7S
78mm, 240V/120W bulb.
NOTE: Always use a cloth or gloves to replace the bulb, as touching it with
bare hands shortens the life considerably.
If this does not resolve your issue, verify that wires 2 and 5 are properly
inserted into the connection block and are connected to the switch for the
light. Refer to Steps 12 and 13.
No heat
None of the elements are heating. Verify that wires 2, 3, 4 and 5 are properly
connected. Refer to steps 12 and 13.
Only some elements are heating
If some elements are not working (see steps 12 and 13) and verify that wires 2,
3, 4 and 5 are securely connected in the proper terminals.
Nothing works
Verify all wires are properly inserted in the connector block and are wired to
the wall switches. Refer to steps 12 and 13.
Verify that the circuit breaker switch is turned on and has not been tripped.
Close the control box and retry.
If still not working, please contact your dealer.