1.
Electrical safety procedures &
requirements
The use of the DISC requires an electrical installation with reliable safety
grounding. The installation's electrical safety can only be guaranteed if
the device has been correctly connected to a grounding (earthing) system
built in accordance with the safety instructions. A preliminary inspection is
absolutely essential. In the event of any uncertainty, a careful inspection
must be made by a qualified and authorized technician. Heatsail will not be
held responsible for injury and/or damage resulting from an ungrounded
installation.
The installation of the DISC's electrical components requires a main
connection of 240V-50/60Hz (16 amp fuse and appropriate RCD); the
connection must be properly implemented in accordance with the
applicable IEC-CEI standards.
Please note: This product must be installed by a licensed electrician
and the power supply connection should be in accordance with the
requirements of NFPA 70 and OSHA Regulations 29 CFR 1910.304(b)(2).
Statutory and other local regulations may apply.
Before carrying out any maintenance or other work, the power supply
must be disconnected by a licensed electrician. Use Lock-out/Tagout
procedures to ensure that the power can't be switched on again
accidentally.
Adapters, power strips and extension cords may not be used for the
DISC's electrical supply. A switch must be installed between the DISC
and the fuse box at all times. Noncompliance with these instructions may
compromise the safety of the device. Heatsail will not be held liable for
any damage resulting from these issues.