Electrical safety procedures
& requirements
The use of the BEEM requires an electrical system with sound safety
grounding. The electrical safety of the device is only assured if it is
correctly connected to a grounding system built in accordance with
safety regulations. It must be inspected before use. If anything is unclear,
a qualified and authorized person must be consulted. Heatsail is not
responsible for damage caused by an ungrounded device.
The installation of the BEEM electrical components requires a main
connection of 240V-50/60Hz (16 Amp fuse AND 30 mA RCD for the single
BEEM, 20 Amp fuse AND 30 mA RCD for the double BEEM): the connection
must be properly implemented in accordance with the applicable IEC-CEI
standards and local ordinances.
This product must by installed by a licensed electrician and the power
supply connection should be in accordance with the requirements of
NFPA 70 and OSHA Regulations 29 CFR 1910.304(b)(2).
Please note: Statutory and other local regulations may apply. The
electrical power supply will need to be interrupted using lock-out/tag-out
procedures before work on the electrical components can be carried out.
Electric adapters, power strips and/or extension cords may not be used
for the BEEM electrical supply. A switch must be installed between the
BEEM and the fuse box at all times. Non-compliance with these instruc-
tions may compromise the safety of the device. Heatsail will not be held
liable for any damage resulting from these issues.