DRYER OPTION TECHNICAL INFORMATION 60Hz

General

Refrigerant type
Refrigerant charge
kg (lbs)
Refrigerant oil
Control settings
Hot gas setting
barg (psig)
High pressure switch setting
barg (psig)
Fan pressure switch setting
on/off
barg (psig)
Performance
(2) (3)
Dew point temperature at rated
conditions and flow
(3)
Maximum ∆P across dryer
barg (psig)
(1)
In accordance with PNEUROP PN8NTC2.3
(2)
In accordance with ISO 7183 at the modified rated conditions.
(3)
60Hz machines: 85_F ambient, 125 psig inlet.
(4)
40hp 200v unit dewpoint is 50_F (10_C)
INSTALLATION / HANDLING
1.8 (0.84)
Emkarate RL32CF or Texaco Capella HFC32
72 – 74 (5.0 – 5.1)
425 (29.3)
225 / 175 (15.5 / 12.1)
30 / 40HP
(4)
41_F (5_C)
2.2 (0.15)
R404A
50HP
50_F (10_C)
3.0 (0.21)
SSR UP6 40, SSR UP6 50PE, SSR UP6 50PEI, HF50–PE, EP50–PE,
17
HP50–PE, HXP50–PE