Ingersoll Rand SSR UP6 40 Manuel D'utilisation Et D'entretien page 45

Table des Matières

Publicité

Les langues disponibles

Les langues disponibles

SETTING THE PRESSURE SWITCH (where used)
TO CHECK THE MAXIMUM DISCHARGE PRESSURE
(Pressure switch upper trip point)
Slowly close the isolation valve located adjacent to the compressor.
Observe the rise in pressure and ensure that the pressure switch
opens (and unloads the compressor) at the correct Maximum
discharge pressure.
The maximum discharge pressure is shown on the machine data plate.
DO NOT exceed these figures.
MAINTENANCE
1
TO CHECK THE LOWER SET POINT
Observe the line pressure fall and note the point at which the
pressure switch closes (and loads the compressor).
TO ADJUST THE UPPER SET POINT
Remove the transparent cover and turn the adjuster [1]. The red
pointer will move. Turn the adjuster anti–clockwise to increase the set
point or clockwise to decrease it.
TO ADJUST THE LOWER SET POINT
Remove the transparent cover and turn the adjuster [2]. The green
pointer will move. Turn the adjuster anti–clockwise to increase the set
point or clockwise to decrease it.
NOTE
The pressure switch scale is a guide only. Use the machine
pressure gauge to verify the upper and lower set points.
SSR UP6 40, SSR UP6 50PE, SSR UP6 50PEI, HF50–PE, EP50–PE,