Installation B Automatic Entry Or Exit - BFT PERSEO CBE FW 1.2.X Manuel D'installation Et D'utilisation

Table des Matières

Publicité

Les langues disponibles
  • FR

Les langues disponibles

This solution is recommended when you want to allow entry to a reserved area, without using any commands, allowing transit of vehicles in
just one direction.
Loops S1 and S2 also have a safety function in that they will not let the bollard to ove all the ti e if the vehicle is over S1 or S2.
- Connect the N.O. contact of the coil receiver S1 to the OPEN input.
- Connect the N.O. contact of the S2 loop receiver to the CLOSE input.
- The dimensional values given are only appro imate.
*
We suggest installing the "RME 2" metal mass detector.
PARAMETER





INSTALLATION B
13.2
RECOMMENDED DIMENSIONS
DATA
DESCRIPTION

The close command acts as a close-when-released and safety function.

Radio channel 1: Disabled

Opening consent

Semiautomatic logic

Command during pause is OFF
AUTOMATIC ENTRY OR EXIT
The vehicle approaches the
reserved area. When over the
loop S1, the bollard goes down.
When the vehicle is no longer
over loop S2, the bollard will
rise again.
PERSEO CBE