Mounting Supplies
The following items will be needed to mount the sensors:
● Flat blade screwdriver
● Mounting Frames or Mounting tracks
● Tape, chalk and a ruler or measuring tape
● Mounting Straps
● Spacer Bar
● Mounting Guide (for Direct Mount)
● CC129 Pipe Damping Film
● Ultrasonic coupling compound
● Sensors (matched set)
3.5.2

Reflect Mount using Spacer Bar

The spacer bar eliminates manual spacing measurements and provides rigidity for mounting
the sensors while maintaining axial alignment. Refer to Programming the Transmitter
(Page 30) before proceeding.
Ltn Menu Cell
The view only menu cell show the distance in inches and millimeters between the front faces
of sensors along the axis of the pipe. If sensors are mounted without a mounting track or
spacer bar then spacing must be done with the Ltn value. Note that the Ltn value may be a
negative number for direct mount on very small pipes where sensor spacing overlaps.
FUG1010 IP65 NEMA 4X Quick Start
Operating Instructions, 06/2014, A5E02951527-AC
Connecting
3.5 Sensor Installation
39