Connecting
3.4 Programming the Transmitter
The table below indicates the viscosity, specific heat ratio and estimated sound velocity (Vs)
for some common gases. The default "Gas Parameters" are suitable for natural gas.
Table 3- 3
Carbon Monoxide
Ethane
Helium
Hydrogen
Methane
Natural Gas
Nitrogen
Oxygen
Standard Volume Compensation
If a direct standard volume output is required from the meter, then the entry of an AGA8
compensation table may be needed. Refer to the manual for further details on configuring
the meter for standard volume compensation.
Sensor Identification
The sensor part number located on the front face provides a detailed identification. For
example, the Part Number: 1011GCHNFS-C2T1-S2 means:
Note
Check to make sure that the sensors are a matched set with the same serial numbers and
marked with an "A" and "B" (e.g., 19256A and 19256B).
34
Common Gases for Clamp-On Measurement (at 14 BAR & 15.5°C / 200 PSIA & 60°F)
Gas
Viscosity (cP)
Model
Hi Precision
NEMA w/F-Conn
Pipe Material
Spec. heat Ratio
(Cp/Cv)
0.017
0.010
0.019
1.410
0.011
0.011
0.017
0.020
Size
Temperature Range
Agency Approved
Operating Instructions, 06/2014, A5E02951527-AC
Estimated Vs (m/s)
1.43
1.32
1.66
1.41
1.35
1.33
1.42
1.42
FUG1010 IP65 NEMA 4X Quick Start
348
281
1006
1306
437
400
348
324