LEG/CASTER ASSEMBLY
The unit is provided with 6"(152 mm) adjustable stainless steel legs (hardware included). A set of 6"(152
mm) casters (adjustable or non- adjustable) are available as an optional field installable accessory.
Installation of Legs/Casters:
1. Carefully tip unit on its side.
2. Thread leg/caster mounting stem into weld nuts provided on the bottom of unit located in each of the
four corners.
3. After all legs/casters have been installed, carefully return the unit to its upright position.
(For additional leg information, see ―LEVELING section of this manual).
A permanently connected appliance mounted on casters and intended to be secured to the building
structure should adhere to the following:
Adequate means must be provided to limit the movement of the appliance without depending
on or transmitting stress to the electrical conduit
The location(s) where restraining means are to be attached to the appliance needs to be on
the outside rear parts of the chassis frame. Use the connection points provided.
The appliance shall be installed using a flexible conduit.
If the unit is installed on casters and is moved for any reason, it is recommended that it be re-leveled front
to back and side to side before resuming operation.
LEVELING
To level the unit, place a carpenter's level on the unit top and check leveling of the unit side to side and
front to rear. Achieve leveling by turning each foot section of the unit's leg as needed. Turning the foot in
a counter clockwise direction will increase height and clockwise will decrease.
DRAIN
Unit comes equipped with a drain pipe for emptying the contents of the tank for disposal. A catch basin
for this drain must be put in place before attempting to use the unit. This can be accomplished through
the use of the optional Drain Caddy, a standard ½ or ⅔ size hotel pan, or through connecting the unit to a
floor drain. If using a floor drain, ensure that plumbing and waste effluent are in compliance with all local
codes. DO NOT DISPOSE OF USED GREASE OR OIL THROUGH A FLOOR DRAIN.

ELECTRICAL CONNECTIONS

Electrical and grounding connections must comply with the applicable portions
of the National Electrical Code and/or other local electrical codes.
Disconnect the electrical power to the machine and follow Lockout / Tagout
procedures.
The unit is designed for 208 or 240 volt, three phase power supply only. Do not attempt to connect the
unit to any other type of power supply, the unit will not operate on a single phase supply. The unit has a
current draw of 25 amps per leg, make sure to use the appropriate size disconnect for your locality.
Position the unit in its final location. Bring conduit containing the proper supply wire to the unit through
the knock out located on the back of the unit. Select the size and type of field wire in accordance with
the National Electrical Code suitable for carrying the equipment's rated amps and voltage. Use field wires
suitable for 75°C (167°F).
Connect supply leads to field terminal block and grounding lead to the labeled ground lug. The supply
wire should be anchored through the access hole with a bulkhead fitting.
- 5 -