PRINCIPLE OF OPERATION

The DAME stove is completely airtight with respect to the
room in which it is installed; this means that the air (for
combustion and glass-cleansing) is taken directly from the
external environment, thus avoiding even minimum use of
the air of the room in which it is installed.
It is consequently suitable for use in houses defi ned at
"PASSIVE".
To respect this hermetic property of the stove, the pipe for the
input of the comburent air must be connected with the external
environment using suitable airtight pipes and connections.
The stove produces hot air using wood pellets as fuel, with
electronically controlled combustion. Hereunder is the explana-
tion of its functions (the letters refer to fi gure 1).
The fuel (pellets) is provided by the storage hopper (A) and,
to the combustion chamber (D) by means of a feed screw (B),
which is driven by a gear motor (C).
The pellets are ignited by the air that is heated by an electrical
resistance (E) and drawn into the combustion chamber
by a smoke extractor (F).
The smoke produced by combustion are extracted from the
combustion chamber by the same extractor fan (F) and expelled
from the vent (G) which can be connected to the back or on the
top of the stove (see page 38).
The stove can function using natural convection or forced
ventilation (which may be disabled) to heat only the room in
which it is installed (front fan) or alternatively an adjacent or
other room (rear fan).
In order to channel hot air to another room, it is necessary to
use the following optional kits (more details on page 42-43).
- KIT 12 for distributing hot air to an adjacent room
- KIT 12 BIS for distributing hot air to a remote room
The combustion chamber, with base and ceiling in Vermiculite,
closed at the front by a door in ceramic glass.
Fuel quantity, smoke extraction and combustion air supply
are all controlled by an electronic control board, which is
®
equipped with Leonardo
software to achieve high combustion
effi ciency and low emissions.
All phases of operation can be managed via radio remote
control.
The stove is equipped with a serial port to connect an optional
cable (code 640560) to be connected to devices that allow
remote ignition (e.g. remote telephone, local thermostat, ect.)