Batteries: Removal; Periodic Checks; Display Alarms - Dustbane Gladiator 464 Manuel D'opération

Masquer les pouces Voir aussi pour Gladiator 464:
Table des Matières

Publicité

Les langues disponibles

Les langues disponibles

Batteries: removal

! DANGER: When removing the batteries, the operator must be equipped with suitable personal protection devices (gloves, goggles,
overalls, safety shoes, etc) to reduce the risk of accidents. Make sure the switches on the control panel are in the "0" position (off) and the
machine is turned off. Keep away from naked flames, do not short circuit the battery poles, do not cause sparks and do not smoke.
Should it become necessary to replace the battery, contact a specialist technician approved by Dustbane or take the machine to
any Dustbane service centre. The battery is a sealed unit and guaranteed safe under normal circumstances; in the unlikely event of
fluid leaking from the battery, do not touch the fluid and be sure to take the following precautions:
• Contact with the skin can cause irritation; wash with soap and water.
• Inhalation of vapours can cause irritation to the airways; stay out in the open air and consult a doctor.
• Contact with the eyes can cause irritation; flood the eyes with water immediately and thoroughly for at least 15 minutes,
and consult a doctor.

Periodic Checks

Checks
The belts for slackening
The tightnwess of nuts and screws
The brushes for wear
The gaskets for wear and leakages
If all the functions are in working order
Empty hopper
Remove and shake pre-filter
Check main filter

Display Alarms

Alarm
C22
C14
FS0
SP1
Yellow LED lit
Red LED flashes
P1.X
P2.X
SF.X
12
Operations Manual
Error indicator
Short circuit brush protection: Reset by
turning OFF the stops all functions.
Dissipater at high temperature. Activates
if temperature is over 194° F.
Worn brushes.
Brushes KO.
Battery in reserve.
Battery discharged.
Sweeping mode 1 button programming
activated.
Sweeping mode 2 button programming
activated.
Filter shaker program setting activated.
Gladiator 464/664
Daily
Weekly
Operations
Operations
X
X
X
X
X
X
What to do
Reset by turning OFF the machine and
starting again.
The machine resets when temperature
lowers under 176° F.
Replace brush.
Error can only be reset by turning off
the machine. This alarm condition arises
if the brushes are put in SHUTDOWN
condition three times in a minute.
Machine continues to work. Only
a warning that the battery is near
discharge.
Machine stops all functions. Turn off
machine and charge the battery.
See programming.
See programming.
See programming.
Six Monthly
Operations
X
X
X
X