Bertos G6F2BH6 Mode D'emploi page 112

Masquer les pouces Voir aussi pour G6F2BH6:
Table des Matières

Publicité

Les langues disponibles
  • FR

Les langues disponibles

  • FRANÇAIS, page 118
110 |
Check of operation
Ensure that the type of nozzles used corresponds to
that shown in the table on burners. Check whether the
pressure reducer used has a flow rate greater than the sum
of the consumption flow rate of all connected equipment.
Check that the gas supply pipes are adequate.
Checking the oven and gas rings pilot light
When correctly adjusted, the pilot light flame will
completely surround the thermocouple; if it does, adjust
by turning the gas and/or primary air adjusting screw.
Checking the primary air
The burners of the ovens solid top are fitted with a primary
air regulator.
In the table on burners. The measure of adjustment H is
given.
Checking the functions
- Start the appliance;
- Check the gas tubes for leaks;
EN
- Check the burner flame, also at minimum.
Note for the installer
- Explain and demonstrate to the user how the machine
works according to the instructions, and hand him this
manual.
- Remind the user that any structural alterations to the
room housing the appliance may affect the combustion
air supply.
Running the appliance on other types of gas
To change over to another type of gas, for example from
methane to liquid, use the correct type of burner in
accordance with the table on burners.
The nozzles for the burners and pilot light for different
types of gas, marked in 100ths of mm, are in a case
supplied with the appliance.
When the appliance has been transformed or adapted,
recheck its functions as described in paragraph "Checking
the functions".
Replacing the burner nozzles (gas rings Fig. 2)
To replace nozzle (1), remove the grid, the burner cap, the
burner and the spill tray.
Replace nozzle (1) (see table on burners).
Adjusting the low flame (gas rings)
Adjust the low flame screw as follows:
- when using LPG, tighten the minimum adjustment
screw (2) all the way down;
- when using natural gas, turn on the appliance. Turn
the knob to low and regulate the flow with screw (2)
(clockwise = decrease in flow; counter-clockwise =
increase in flow).
Adjustment of the pilot nozzle (burners open - Fig. 2)
Remove the grille and the tub from the top, remove the
closure (3) and use a screwdriver to adjust the nozzle (5).
The nozzle is correctly set when the flame surrounds
GAS RINGS
MOD.
N°:
the thermocouple. When using LPG, the adjusting screw
Qn
should be completely tightened. Replace the closure (3)
V
kW:
Hz: 50/60
and gasket (4).
Check the primary air
After changing the nozzle, as described above, check
that measure H (fig. 2) of the primary air adjustment is in
accordance with the data in the table on burners.
FG1 SERIES GAS OVEN
Replacing the burner nozzle (gas oven type FG1 Fig. 3)
To gain access to the oven burner simply remove the
bottom panel (inside the cooking chamber).
Remove the screw D and extract the burner by pulling
it outwards while taking care not to damage the
thermocouple fixed to the burner. Use the special spanner
to loosen injector C and replace it with the right one for
the type of gas used.
To fit the burner back on again, follow the same instructions
in reverse order.
Checking the primary air
Before putting the burner back in place, check that size
H referred to the position of the air regulator clamp E is in
accordance with the table on burners.
Adjusting the low flame (gas oven FG1 Fig. 3)
After having removed the contro panel, adjust the low
flame screw (N) as follows:
- when using LPG, it should be fully screwed down;
- if natural gas is used:
1- Find the knob of the corresponding cock.
2- Turn the burner on and turn it to the minimun output
position.
3- Adjust the minimun flow by means of the screw N. The
flow increases by loosening the screw and decreases by
tightening it.
4- Once the flame is considered suitable for a minimum
setting , check that it corresponds to the minimum
capacity indicated in the table on burners.
5- If the power is less than the value in the table, turn the
minimum screw again and repeat the check
6- If the power is greater than the value indicated in the
table, tighten the minimun flow screw and repeat the
check.
FG SERIES GAS OVEN AND TUTTOFORNO T
Replacing the burner nozzle
(gas oven type FG Fig. 4.1)
Remove the bottom panel. Loosen screw (2) fixing the
primary air bushing and push the latter into the Venturi
tube.
The nozzle is now perfectly accessible.
After replacing the nozzle according to the type of gas
being used and the technical data, reassemble everything
and adjust measure "H" (see table on burners).
Replacing the burner nozzle (Tuttoforno T Fig. 4.2)
Remove the bottom panel inside the cooking chamber.
For FGP also remove the flame separator.