DISCONNECTING PROPANE CYLINDER:
1. Turn all the grill knobs to off.
2. Turn the tank valve off fully (turn clockwise to stop).
3. Detach the regulator from tank valve by turning the black (QCC) nut counterclockwise.
Install the protective cap back onto the threads of the propane cylinder valve.
4.

FUEL TYPE:

The following instructions are for Natural Gas configured grills ONLY. Operating Pressure = 4" WC.
BUILT IN NATURAL GAS HOOK-UP: (Fig. 9)
1. The piping up to the gas grill is the responsibility of the installer and piping should be located as shown
below.
2. The connector must not pass through a wall, floor, ceiling or partition, and is protected from damage.
3. Do not use a hose to connect the unit except to connect the cylinder regulator to the piping system.
4. The gas supply pipe must be sufficiently sized to supply the BTU/h specified on the rating plate, based on
the length of the piping run.
!WARNING!
1 Never insert any foreign objects in the quick
release or Natural Gas hose, as this may cause
leaks.
2 Pressure from the gas source for this grill and its
appliance regulator (set at 4" WC) MUST NOT
exceed 7 inches of Water Column; using a grill at
higher pressures could result in property damage,
and injury or death.**
3 Do NOT use this grill until leak tests have been
completed.
4. If a gas leak is detected and cannot be stopped,
call the fire department immediately
** NOTE; this is the maximum inlet pressure rating
for the included Natural Gas Regulator, part number
!WARNING!
1 Never insert any foreign objects in valve outlet, as this
may cause leaks.
2 Do NOT connect this grill to unregulated Propane systems
such as in a motor home or camper trailer. System pressure
MUST be regulated before hook up.
3 Do NOT use this grill until leak tests have been completed.
4. If a gas leak is detected and cannot be stopped, call the
fire department.

Natural Gas Connection:

.
JF-99
Figure 9
Regulator set at
4" WC (Natural
Gas)
Typical
Bottom Gas
connection
Installer
supplied gas
shutoff valve
(must be
easily
accessible)
Typical Natural Gas Connection
CAUTION: Provide adequate ventilation holes in the enclosure for safety
purposes in the event of a gas leak.