Natural Gas Connection; Installation Codes - Jackson Grills Keystone Série Manuel D'utilisation

Table des Matières

Publicité

Les langues disponibles

Les langues disponibles

FUEL TYPE:
The following instructions are for Natural Gas configured grills ONLY.
Operating Pressure = 4" WC.

INSTALLATION CODES:

Please refer to page 2, item #1 of this manual.
CART: CONNECTING THE NATURAL GAS HOSE:
1. Use only the natural gas hose supplied with your Natural Gas configured
grill.
2. Install the supplied hose onto the flare nut nipple on the fuel regulator,
located on the RH inner side of the pedestal (Fig.8). DO NOT USE
SEALANT of any kind. Tighten using a ¾" open end wrench or a crescent
wrench. Hold the regulator nut with a second wrench while tightening.
3. A female quick release is included with the grill. Install it onto the homeowner's
preexisting natural gas quick release box for 2lb NG systems (high to low pressure
system) (Fig. 9) or 7" WC NG connection (Fig 10). The gas safety shut-off valve should
be in an easy to access location (see Fig.11) NOTE; pipe dope or Gas Rated Teflon tape
must be used to seal the threads at this connection.
4. To connect quick connect, push back sleeve of socket, insert plug release sleeve. Push
plug until sleeve snaps forward, locking plug in socket. This turns the gas ON
automatically. To disconnect, push sleeve back and pull out plug. This automatically
turns OFF the gas (Fig.12).
5. Check supply pressure to ensure that incoming pressure to the inlet side of the 4" WC
Regulator on the NG appliance is no higher than 7" Water Column.
6. Use a soapy water solution to check all connections for leaks before lighting grill. If a leak
found DO NOT use the grill. Turn gas off and call a professional gas fitter to repair the
leak.
Fig. 10
!WARNING!
Always take a leak test before
lighting the grill to prevent a
possible fire or explosion
!ATTENTION!
Always turn grill knobs OFF,
before installing gas lines, or
making any connections and
diconnections of supply hoses.

Natural Gas Connection:

Fig. 11
1 Never insert foreign objects into the trigger housing or natural gas
pipe as this may cause leaks.
2 The pressure of the gas source for this barbecue must not exceed 14
inches of water column; using the barbecue at higher pressures could
result in property damage, personal injury or death. **
3 DO NOT use this grill until leak tests are performed.
4. If a gas leak is detected and can not be stopped, call the fire
department immediately.
** NOTE: This is the maximum nominal inlet pressure for the included
natural gas regulator, part number JF-99
!WARNING!
10
Fig. 8
Fig. 9 (BC
Application)
7" WC
2lb
NG
is
Fig. 12

Publicité

Chapitres

Table des Matières
loading